Trident Titan Pro 08M – HB
Item Number: C00954
Guarantee: 10 years
Trident Titan Pro 08M-HB Hydrosplit Heat Pump
The Trident Titan Pro 08M-HB is a hydrosplit heat pump designed for both heating and cooling, featuring a Trident Titan Pro 08M monoblock outdoor unit and an HB hydrobox indoor hydraulic unit. The unit uses R290 refrigerant, a Hitachi twin rotary piston compressor, and a Grundfos circulation pump. Its maximum heating capacity under A7/W35 conditions is 9.6 kW, and it can produce heating water temperatures of up to 75 °C.
The SCOP of 5.23 specified for a water temperature of 35 °C indicates high seasonal heating efficiency. The HB indoor unit features an ESBE three-way valve and 2 × 3 kW backup/supplementary heating. The unit is quiet and also offers a reduced-noise night mode; in the latter, the maximum sound power level is 42 dB(A). The data sheet also lists a free remote monitoring service and 3 years of free maintenance.
Key features
Hydrosplit system with a monoblock outdoor unit and an indoor hydrobox.
Heating and cooling mode.
Heating water temperature up to 75 °C.
R290 refrigerant.
Hitachi twin rotary piston compressor.
Grundfos circulation pump.
ESBE three-way valve in the indoor unit.
2 × 3 kW backup/supplemental heating.
Quiet and reduced-noise night mode.
Free remote monitoring service.
According to the product sheet, it comes with 3 years of free maintenance and up to 10 years of comprehensive warranty coverage.
Technical data
Basic Data and Energy Efficiency
Full system name: Trident Titan Pro 08M-HB.
Outdoor unit: Trident Titan Pro 08M.
Indoor hydraulic unit: HB (Hydro Box).
Heating energy efficiency class according to the product data sheet, at 35 / 55 °C: A+++ / A+++.
Seasonal Coefficient of Performance (SCOP) at 35 / 55 °C: 5.23 / 3.89.
Seasonal Energy Efficiency Ratio (SEER) at 18 / 7 °C: 6.8 / 4.23.
Rated heat output (Prated) at 35 / 55 °C: 7.34 / 7.31 kW.
Maximum heat output at 35 / 55 °C: 9.6 / 9.2 kW.
Annual heating energy consumption according to the data sheet, at 35 / 55 °C: 2901 / 3881 kWh.
Heating Capacity
Heating capacity range for A7/W35: 2.9–9.6 kW.
Heating capacity range for A2/W35: 3.91–9.38 kW.
Heating capacity range for A−7/W35: 2.96–8.52 kW.
Electric power consumption for the A7/W35: 1.90 kW.
Heating efficiency (COP) for A7/W35: 5.05.
Heating capacity for A7/W55: 9.2 kW.
Electric power consumption for the A7/W55: 2.38 kW.
Heating efficiency (COP) for A7/W55: 3.87.
Maximum heating capacity in quiet mode, for A−7/W35: 6.48 kW.
Maximum heating capacity in quiet mode, for A−7/W55: 5.7 kW.
Cooling Capacity
Cooling capacity for the A35/W18: 9.04 kW.
Electric power consumption for the A35/W18: 2.46 kW.
Cooling capacity for the A35/W7: 7 kW.
Electric power consumption for the A35/W7: 2.34 kW.
Maximum cooling capacity in quiet mode for the A35/W18 model: 7.45 kW.
Maximum cooling capacity in quiet mode for the A35/W7 model: 5.68 kW.
Cooling Circuit
Refrigerant: R290.
Refrigerant charge: 0.9 kg.
Compressor: Hitachi twin rotary piston.
Compressor oil: POE.
Electrical Specifications
Rated voltage of the outdoor unit: 230 V.
Recommended fuse for the outdoor unit: 1 × B20 A.
Nominal voltage of the HB indoor unit: 230 V.
Recommended fuse for the HB indoor unit: 1 × B16 A.
Voltage of the backup/auxiliary heating system: 400 V.
Recommended fuse rating for the safety/auxiliary heater, according to the data sheet: 2 × B16 A.
Safety/auxiliary heating output: 2 × 3 kW.
Hydraulic Data
Outdoor unit water-side pipe connection: G1″, male thread.
Indoor unit water-side pipe connection: G1″, female thread.
Nominal volume flow rate: 1.37 m³/h.
Minimum/maximum air flow rate: 0.94 / 1.8 m³/h.
Internal pressure drop at nominal flow rate: 23 kPa.
Circulation pump: Grundfos UPM4XL K 25-90 130.
Manufacturer of indoor three-way valves: ESBE.
Minimum/maximum operating pressure: 0.8/3 bar.
Operating Range and Fan Specifications
Operating range for external temperature: between −25 and +43 °C.
Heating water temperature: 25–75 °C.
Cooling water temperature: 7–20 °C.
Number of fans: 1.
Fan airflow: 3,280 m³/h.
Noise level
Sound power level according to EN 12102: 49 dB(A).
Maximum sound power level at operating limits: 68 dB(A).
Maximum sound power level in reduced nighttime mode: 42 dB(A).
Dimensions and weight
Outdoor unit dimensions (width × depth × height): 1260 × 400 × 1000 mm.
Weight of the outdoor unit: 125 kg.
Dimensions of the HB indoor unit (width × depth × height): 550 × 260 × 650 mm.