Trident Titan Pro 12M-AIO Heat Pump with Integrated DHW Tank

The Trident Titan Pro 12M-AIO is a heat pump system designed for heating, cooling, and domestic hot water supply; it consists of a Trident Titan Pro 12M monoblock outdoor unit and an AIO indoor unit that includes a 250-liter DHW storage tank. The system uses R290 refrigerant, a Hitachi twin rotary piston compressor, an Alfa Laval plate heat exchanger, and a Grundfos circulation pump. Its maximum heating capacity under A7/W35 conditions is 12.5 kW, and the heating water temperature can reach up to 75 °C.

The SCOP of 5.48 specified for a water temperature of 35 °C indicates high seasonal heating efficiency. The AIO indoor unit features an ESBE three-way valve, a 12-liter expansion tank, and 3 × 3 kW backup/supplemental heating. The outdoor unit is quiet and also offers a reduced nighttime operating mode; in the latter, the maximum sound power level is 45 dB(A). According to the data sheet, the product includes a free remote monitoring service and 3 years of free maintenance.

Key features

  • Monoblock outdoor unit and AIO indoor unit with integrated DHW storage tank.
  • Heating, cooling, and domestic hot water supply functions.
  • A built-in 250-liter domestic hot water storage tank.
  • Heating water temperature up to 75 °C.
  • R290 refrigerant.
  • Hitachi twin rotary piston compressor.
  • Alfa Laval plate heat exchanger.
  • Grundfos circulation pump.
  • ESBE three-way valve.
  • 12-liter expansion tank.
  • 3 × 3 kW backup/supplemental heating.
  • Quiet and reduced-noise night mode.
  • Free remote monitoring service.
  • 3 years of free maintenance.
  • Up to a 10-year comprehensive warranty.

Technical data

Basic Data and Energy Efficiency

  • Full system name: Trident Titan Pro 12M-AIO.
  • Outdoor unit: Trident Titan Pro 12M.
  • Indoor unit: AIO (All-in-One), with integrated DHW storage tank.
  • Heating energy efficiency class according to the product data sheet, at 35 / 55 °C: A+++ / A+++.
  • Seasonal Coefficient of Performance (SCOP) at 35 / 55 °C: 5.48 / 4.12.
  • Seasonal Energy Efficiency Ratio (SEER) at 18 / 7 °C: 7.62 / 4.66.
  • Rated heat output (Prated) at 35 / 55 °C: 9.83 / 9.6 kW.
  • Seasonal heating energy efficiency at 35 / 55 °C: 216 / 162%.
  • Annual heating energy consumption according to the data sheet, at 35 / 55 °C: 3706 / 4812 kWh.

Heating Capacity

  • Heating capacity range for A7/W35: 3.55–12.5 kW.
  • Heating capacity range for A2/W35: 4.89–11.78 kW.
  • Heating capacity range for A−7/W35: 4.01–10.8 kW.
  • Electric power consumption for the A7/W35: 2.61 kW.
  • Heating efficiency (COP) for A7/W35: 4.81.
  • Maximum heating capacity in quiet mode, for A−7/W35: 8.46 kW.
  • Maximum heating capacity in quiet mode, for model A−7/W55: 7.86 kW.

Cooling Capacity

  • Cooling capacity for A35/W18: 12.18 kW.
  • Electric power consumption for the A35/W18: 2.95 kW.
  • Cooling capacity for the A35/W7: 9.21 kW.
  • Electric power consumption for the A35/W7: 2.78 kW.
  • Maximum cooling capacity in quiet mode for the A35/W18 model: 11.23 kW.
  • Maximum cooling capacity in quiet mode for the A35/W7: 8.47 kW.

Cooling Circuit

  • Refrigerant: R290.
  • Refrigerant charge: 1.2 kg.
  • Compressor: Hitachi twin rotary piston.
  • Compressor oil: POE.

Electrical Specifications

  • Rated voltage of the outdoor unit: 400 V.
  • Recommended fuse rating for the outdoor unit: 3 × B16 A.
  • Rated voltage of the AIO indoor unit: 230 V.
  • Voltage of the backup/auxiliary heating system: 400 V.
  • Recommended fuse rating for the backup/auxiliary heater: 3 × B16 A.
  • Safety/auxiliary heating capacity: 3 × 3 kW.

Hydraulic Data and Hot Water Storage Tank

  • Heat exchanger: Alfa Laval plate heat exchanger.
  • Outdoor unit water-side pipe connection: G1″, male thread.
  • AIO indoor unit water-side pipe connection: G1″, female thread.
  • Nominal volumetric flow rate: 2.05 m³/h.
  • Minimum/maximum air flow rate: 1.44 / 2.7 m³/h.
  • Internal pressure drop at nominal flow rate: 23 kPa.
  • Circulation pump: Grundfos UPM4XL K 25-90 130.
  • The capacity of the domestic hot water storage tank is 250 liters.
  • The capacity of the HMV storage coil is 25 liters.
  • Surface area of the HMV storage tank's coiled pipe: 3.4 m².
  • Manufacturer of three-way valves: ESBE.
  • Expansion tank capacity: 12 liters.
  • Minimum/maximum operating pressure: 0.8/3 bar.

Operating Range and Fan Specifications

  • Operating range for external temperature: between −25 and +43 °C.
  • Heating water temperature: 25–75 °C.
  • Cooling water temperature: 7–20 °C.
  • Number of fans: 1.
  • Fan airflow: 5,000 m³/h.

Noise level

  • Sound power level of the outdoor unit according to EN 12102: 50 dB(A).
  • Maximum sound power level at operating limits: 70 dB(A).
  • Maximum sound power level in reduced nighttime mode: 45 dB(A).

Dimensions and weight

  • Outdoor unit dimensions (width × depth × height): 1260 × 400 × 1000 mm.
  • Outdoor unit weight: 140 kg.
  • Dimensions of the AIO indoor unit (width × depth × height): 590 × 705 × 1950 mm.
  • According to the data sheet, the AIO indoor unit weighs 250 kg.


 