Trident Titan Pro 15M-HB Hydrosplit Heat Pump

The Trident Titan Pro 15M-HB is a hydrosplit heat pump designed for both heating and cooling, featuring a Trident Titan Pro 15M outdoor unit and an HB indoor hydraulic unit. The unit features R290 refrigerant, a Hitachi twin rotary piston compressor, an Alfa Laval plate heat exchanger, and a Grundfos circulation pump. Its maximum heating capacity under A7/W35 conditions is 15.2 kW, and it can produce heating water temperatures of up to 75 °C.

The SCOP of 5.35 specified for a water temperature of 35 °C indicates high seasonal heating efficiency. The HB indoor unit from LK – Sweden features a three-way valve and 3 × 3 kW backup/supplemental heating. The outdoor unit, equipped with two fans, is quiet and also offers a reduced nighttime operating mode; in the latter, the maximum sound power level is 48 dB(A). According to the data sheet, the product includes a free remote monitoring service and 3 years of free maintenance.

Key features

  • Hydrosplit system, with an outdoor unit and an indoor hydrobox.
  • Heating and cooling mode.
  • Heating water temperature up to 75 °C.
  • R290 refrigerant.
  • Hitachi twin rotary piston compressor.
  • Alfa Laval plate heat exchanger.
  • Grundfos circulation pump.
  • LK – Sweden three-way valve in the indoor unit.
  • 3 × 3 kW backup/supplemental heating.
  • Outdoor unit with two fans.
  • Quiet and reduced-noise night mode.
  • Free remote monitoring service.
  • 3 years of free maintenance.
  • Up to a 10-year comprehensive warranty.

Technical data

Basic Data and Energy Efficiency

  • Full system name: Trident Titan Pro 15M-HB.
  • Outdoor unit: Trident Titan Pro 15M.
  • Indoor hydraulic unit: Trident Titan Pro HB.
  • Heating energy efficiency class according to the product data sheet, at 35 / 55 °C: A+++ / A+++.
  • Seasonal Coefficient of Performance (SCOP) at 35 / 55 °C: 5.35 / 4.01.
  • Seasonal Energy Efficiency Ratio (SEER) at 18 / 7 °C: 7.02 / 4.59.
  • Rated heat output (Prated) at 35 / 55 °C: 13.10 / 12.41 kW.
  • Maximum heat output according to the summary data in the data sheet, at 35 / 55 °C: 15.92 / 15.10 kW.
  • Seasonal heating energy efficiency at 35 / 55 °C: 211 / 158%.
  • Annual heating energy consumption according to the data sheet, at 35 / 55 °C: 5082 / 6360 kWh.

Heating Capacity

  • Heating capacity range for A7/W35: 4.30–15.20 kW.
  • Heating output range for A2/W35: 7.33–13.95 kW.
  • Heating capacity range for A−7/W35: 5.96–14.50 kW.
  • Maximum heating capacity in quiet mode, for A−7/W35: 10.81 kW.
  • Maximum heating capacity in quiet mode, for model A−7/W55: 10.5 kW.

Cooling capacity in quiet mode

  • Maximum cooling capacity in quiet mode for the A35/W18 model: 12.95 kW.
  • Maximum cooling capacity in quiet mode for the A35/W7 model: 9.90 kW.

Cooling Circuit

  • Refrigerant: R290.
  • Refrigerant charge: 1.8 kg.
  • Compressor: Hitachi twin rotary piston.
  • Compressor oil: POE.

Electrical Specifications

  • Rated voltage of the outdoor unit: 400 V.
  • Recommended fuse rating for the outdoor unit: 3 × B20 A.
  • Nominal voltage of the HB indoor unit: 230 V.
  • Recommended fuse for the HB indoor unit: 1 × B16 A.
  • Voltage of the backup/auxiliary heating system: 400 V.
  • Recommended fuse rating for the backup/auxiliary heater: 3 × B16 A.
  • Safety/auxiliary heating capacity: 3 × 3 kW.

Hydraulic Data

  • Heat exchanger: Alfa Laval plate heat exchanger.
  • Outdoor unit water-side pipe connection: G5/4″, male thread.
  • Indoor unit water-side pipe connection: G1″, female thread.
  • Internal pressure drop at nominal flow rate: 25 kPa.
  • Circulation pump: Grundfos UPMXL 25-125 130 PWM.
  • Manufacturer of indoor three-way valves: LK – Sweden.
  • Minimum/maximum operating pressure: 0.8/3 bar.

Operating Range and Fan Specifications

  • Operating range for external temperature: between −25 and +43 °C.
  • Heating water temperature: 25–75 °C.
  • Cooling water temperature: 7–20 °C.
  • Number of fans: 2.

Noise level

  • Sound power level according to EN 12102: 55 dB(A).
  • Maximum sound power level at operating limits: 72 dB(A).
  • Maximum sound power level in reduced nighttime mode: 48 dB(A).

Dimensions and weight

  • Outdoor unit dimensions (width × depth × height): 1260 × 420 × 1500 mm.
  • Outdoor unit weight: 160 kg.
  • Dimensions of the HB indoor unit (width × depth × height): 550 × 260 × 650 mm.
  • Weight of the HB indoor unit: 34 kg.

 