Trident Titan Pro 20M – HB
Item Number: C00957
Warranty: 10 years
Trident Titan Pro 20M-HB Hydrosplit Heat Pump
The Trident Titan Pro 20M-HB is a hydrosplit heat pump designed for both heating and cooling, featuring a Trident Titan Pro 20M monoblock outdoor unit and an HB indoor hydraulic unit. The unit uses R290 refrigerant and is equipped with a Panasonic twin rotary compressor. Its heating capacity under A7/W35 conditions is 19 kW, and it can produce heating water temperatures of up to 75 °C.
The SCOP of 5.29 specified for a water temperature of 35 °C indicates high seasonal heating efficiency. The HB indoor unit features an ESBE three-way valve and 3 × 3 kW backup/supplementary heating. The outdoor unit, equipped with two fans, is quiet and also offers a reduced nighttime operating mode; in the latter, the maximum sound power level is 51 dB(A). According to the product data sheet, the product includes a free remote monitoring service and 3 years of free maintenance.
Key features
- Hydrosplit configuration, with a monoblock outdoor unit and an indoor hydrobox.
- Heating and cooling mode.
- Heating water temperature up to 75 °C.
- R290 refrigerant.
- Panasonic twin rotary piston compressor.
- ESBE three-way valve in the indoor unit.
- 3 × 3 kW backup/supplemental heating.
- Outdoor unit with two fans.
- Quiet and reduced-noise night mode.
- Free remote monitoring service.
- 3 years of free maintenance.
- Up to a 10-year comprehensive warranty.
Technical data
Basic Data and Energy Efficiency
- Full system name: Trident Titan Pro 20M-HB.
- Outdoor unit: Trident Titan Pro 20M.
- Indoor hydraulic unit: HB (Hydro Box).
- Heating energy efficiency class according to the product data sheet, at 35 / 55 °C: A+++ / A+++.
- Seasonal Coefficient of Performance (SCOP) at 35 / 55 °C: 5.29 / 4.10.
- Seasonal Energy Efficiency Ratio (SEER) at 18 / 7 °C: 7.11 / 4.68.
- Rated heat output (Prated) at 35 / 55 °C: 15.7 / 14.4 kW.
- Seasonal heating energy efficiency at 35 / 55 °C: 209 / 161%.
- Annual heating energy consumption according to the data sheet, at 35 / 55 °C: 6111 / 7270 kWh.
Heating Capacity
- Heating capacity range for A7/W35: 5.9–19 kW.
- Heating capacity range for A2/W35: 8.57–20.58 kW.
- Heating capacity range for A−7/W35: 6.66–17.21 kW.
- Electric power consumption for the A7/W35: 4.35 kW.
- Heating Coefficient of Performance (COP) for A7/W35: 4.37.
- Heating capacity for A7/W55: 17.68 kW.
- Electric power consumption for the A7/W55: 6.16 kW.
- Heating efficiency (COP) for A7/W55: 2.87.
- Maximum heating capacity in quiet mode, for A−7/W35: 13.21 kW.
- Maximum heating capacity in quiet mode, for A−7/W55: 12.05 kW.
Cooling Capacity
- Cooling capacity for the A35/W18: 18.39 kW.
- Electric power consumption for the A35/W18: 5.77 kW.
- Cooling capacity for A35/W7: 12.37 kW.
- Electric power consumption for the A35/W7: 4.06 kW.
- Maximum cooling capacity in quiet mode for the A35/W18 model: 16.18 kW.
- Maximum cooling capacity in quiet mode for the A35/W7: 12.37 kW.
Cooling Circuit
- Refrigerant: R290.
- Refrigerant charge: 1.9 kg.
- Compressor: Panasonic twin rotary piston.
- Compressor oil: PAG.
Electrical Specifications
- Rated voltage of the outdoor unit: 400 V.
- Recommended fuse rating for the outdoor unit: 3 × B20 A.
- Nominal voltage of the HB indoor unit: 230 V.
- Recommended fuse for the HB indoor unit: 1 × B16 A.
- Voltage of the backup/auxiliary heating system: 400 V.
- Safety/auxiliary heating capacity: 3 × 3 kW.
Hydraulic Data
- Outdoor unit water-side pipe connection: G5/4″, male thread.
- Indoor unit water-side pipe connection: G5/4″, female thread.
- Nominal volumetric flow rate: 3.45 m³/h.
- Minimum/maximum air flow rate: 2.41 / 4.46 m³/h.
- Manufacturer of indoor three-way valves: ESBE.
- HB indoor unit minimum/maximum operating pressure: 0.8 / 3 bar.
Operating Range and Fan Specifications
- Operating range for external temperature: between −25 and +43 °C.
- Heating water temperature: 25–75 °C.
- Cooling water temperature: 7–20 °C.
- Number of fans: 2.
- Fan airflow: 6,300 m³/h.
Noise level
- Sound power level according to EN 12102: 59 dB(A).
- Maximum sound power level at operating limits: 74 dB(A).
- Maximum sound power level in reduced nighttime mode: 51 dB(A).
Dimensions and weight
- Outdoor unit dimensions (width × depth × height): 1350 × 440 × 1500 mm.
- Weight of the outdoor unit: 230 kg.
- Dimensions of the HB indoor unit (width × depth × height): 600 × 300 × 700 mm.
- Weight of the HB indoor unit: 38 kg.